CALL GAS
WRITE (I, 170) CHOICE
FORMAT (5X,'FLUID SERVICE:', T60, A)
IF (CVG .GT. 0.0) THEN
WRITE (i, 180) Q, SPG, P21, P22, DELPG, T, CVG
FORMAT (5X,'GAS FLOW RATE, ft^3/hr.: ' , T60, F9.3,/,
* 5X,'SPECIFIC GRAVITY:', T60, F9.3,/,
* 5X,'INLET PRESSURE, psia:', T60, F9.3,/,
*
5X,'OULET PRESSURE, psia:', T60, F9.3,/,
* 5X,'CONTROL VALVE PRESSURE DROP, psi:', T60, F9.3,/,
*
5X,'INLET TEMPERATURE, oF:', T60, F9.3,/,
* 5X,'CONTROL VALVE CAPACITY COEFFICIENT:', T60, F9.3)
ELSE
WRITE (i, 190) Q, SPG, P21, P22, DELPG, T, CVG
FORMAT (5X,'GAS FLOW RATE, ft^3/hr.: ' , T60, F9.3,/,
* 5X,'SPECIFIC GRAVITY:', T60, F9.3,/,
* 5X,'INLET PRESSURE, psia:', T60, F9.3,/,
*
5X,'OUTLET PRESSURE, psia:', T60, F9.3,/,
* 5X,'CONTROL VALVE PRESSURE DROP, psi:', T60, F9.3,/,
*
5X,'INLET TEMPERATURE, oF:', T60, F9.3,/,
* 5X,'CONTROL VALVE CAPACITY COEFFICIENT:', T60, F9.3)
ENDIF
WRITE (I, 200)
FORMAT ( 76 ( IH- ) )
GO TO 5
WRITE (i, 210)
FORMAT (//,20X, 'CONTROL VALVE SIZING FOR STEAM SERVICE',
/, 76( IH* ) )
CALCULATE THE CONTROL VALVE FOR STEAM SERVICE.
CALL STEAM
WRITE (i, 220) CHOICE
FORMAT (SX,'FLUID SERVICE:', T60, A)
IF (CVS .GT. 0.0 ) THEN
WRITE (I, 230) W, F, P31, P32, DELPS, CVS
FORMAT (5X,'CALCULATED STEAM FLOW RATE, ib/hr.:', T60, F9.3,/,
*
5X,'DEGREE OF SUPERHEAT, oF:', T60, F9.3,/,
*
5X,'INLET PRESSURE, psia:', T60, F9.3,/,
* 5X,'OUTLET PRESSURE, psia:', T60, F9.3,/,
* 5X,'CONTROL VALVE PRESSURE DROP, psi:', T60, F9.3,/,
* 5X,'CONTROL VALVE CAPACITY COEFFICIENT:', T60, F9.3)
WRITE (I, 240)
FORMAT (76(IH-))